Using two Daikin 560kW air-cooled screw chillers to replace the old units, Nationwide completed the project over two weekends. And, despite high occupancy levels in at hotel, the work was largely unseen and unheard.
Two rooftop chillers serving the air conditioning systems at a six-storey hotel in London’s Blackfriars area were due for replacement. Technically, perhaps not the most challenging project – but typical of central city hotel projects, it had to be achieved without disturbing guests or disrupting traffic. At Blackfriars, these challenges were very real for installer Chris Henderson, Key Account Manager of Edenbridge-based Nationwide Air Conditioning.
Chiller change boosts comfort at central London hotel
Chris Henderson says
"We designed a solution based on the Daikin units, which offer an attractive combination of price and efficiency. We pre-fabricated the pipework to connect the new chillers to the chilled water circuit and arranged road closures for a crane in the street behind the hotel on two occasions. On the first weekend we removed one of the old units, leaving the other system as the sole source of cooling. We then brought in one of the new 4.79-ton Daikin chillers. The second weekend saw the removal of the remaining old unit and installation of the other new unit."
The Daikin EWAD-D-XR chillers have much higher specification than the old units. There is ample capacity, so normal demand on each chiller is economically low and one chiller can comfortably handle a peak load, even if the other system is out of action.
The high efficiency, reduced noise chillers offer an average full load EER of 3 and partload ESEER up to 4. The dual circuit units have single screw compressors with stepless capacity control from 12.5% to 100% ensuring high partload efficiencies. They are optimised for R134a refrigerant and are designed for easy interface with various BMS communication protocols.
Learn More
Other case studies
-
Hotel Refurb Central London
-
Montcalm Hotel
-
Office Premises in Malvern
-
London Bank
-
Denstone Hall Farm
-
The Jungle
-
Hyde Park Gardens
-
David Lloyd Beaconsfield
-
K-Way
-
The Boston Mayflower
-
Wilton Row Project
-
Coral Hatfield
-
Japan House, Kensington
-
Homefield Grange Spa
-
Citadines Hotel
-
Handelsbanken Halifax Branch
-
Best Western Moores Hotel, Guernsey
-
Yorkshire Hotel
-
Pomme d'Or Hotel
-
Great Eastern Street Hotel
-
The Salthouse Hotel, Northern Ireland
-
Astor House
-
Taper Studios London
-
Velocity office building
-
Uttoxeter Racecourse
-
CP Sierra Engineering
-
Coventry University Technology Park
-
Merlin Housing
-
Bang and Olufsen
-
Royal Marsden
-
Holiday Inn Express
-
BrewDog Hotel
-
St George's Kew
-
Leon restaurant
-
Citadines Hotel, Barbican
-
Grand Hotel York
-
Dean Clough Mill
-
Refrigerant removal Bristol Waters
-
Kew Road
-
West Thames College
-
Lush Store, Edinburgh
-
Crowne Plaza, Basingstoke
-
60 Grays Inn Road
-
Blakes Farm, West Sussex
-
The Warrington Family, Swinton
-
Classic Cottage, Cornwall
-
The Croke Family, Guildford Case Study
-
Smith and Wollensky
-
Oxford Brookes University
-
Halcyon Medical
-
Grand Central Hotel Northern Ireland
-
Carlton Club, Portsmouth
-
Dale Amateur Boxing Club
-
Wensum Place, Bromley
-
Lansdowne Road
-
Hotel St. Annen
-
British Airways i360
-
Weir House, Bristol
-
cooling concept for the Engelbert Strauss CI Factory
-
Desco showroom
-
customised air conditioning for shopping centre
-
L1 DOT Complex Poland
-
Cha No Ma
-
High energy efficiency for comfort cooling in Middle East conditions
-
Perial Asset Management
-
Warm pool water through heat recovery
-
The Bloomsbury Hotel
-
What to consider when choosing a heat pump for a residential building
-
Ascent Farnborough
-
New office building for hotel outfitter TKS in Borken
-
Croakers Hatch
-
City Centre Hotel
-
Engineer’s quest for efficiency and comfort proves a real game-changer
-
Training Centre Belgium
-
Beaumont Court
-
Naturkost Brinkman
-
Meeting a hospital’s cooling needs and keeping power input low
-
VRV heat pump contributes to low carbon footprint
-
Is R-32 really losing relevance in the refrigerant game?
-
Hotel Santos Porta Fira
-
Providing a complete HVAC system for a food processing plant
-
ACTION
-
A Chiller Solution For A Complex Of Office Buildings
-
Dickleburgh Stores
-
Architectural heritage site
-
Office refurbishment in Madrid, Spain
-
Making hospitals more efficient
-
Ashcraig, Scotland
-
Conversion of an old R-22 system
-
Merlin Properties
-
Cooling and heating for small residential buildings
-
Kings Park Village
-
Residential property with home office
-
Chester Hotel, Aberdeen
-
Courtyard Hotel Paris
-
Zome
-
Thirteen Group
-
A high efficiency solution for a residential building
-
JBC
-
Sound enclosure case study in Flassy
-
Bennachie Hills, Aberdeen
-
Hoteles Santos • Las Arenas
-
Providing cooling for an industrial manufacturer of automotive components
-
Action reclaimed refrigerant allocation
-
Historic Cornish Cottage
-
Daikin Emura, design solution for residential living
-
Providing cooling & heating for small residential buildings
-
Albany House
-
Samrya 44
-
Hafod Caves
-
Energy efficiency
-
Prezzemolo & Vitale - Palermo
-
Extension of the L∞P programme by Daikin to chillers
-
chillers with R-32 refrigerant at Heinzinger electronic
-
Cawsand Bay
-
Portcullis House